TRIPP LITE SMARTINT3000VS

TRIPP LITE SMARTINT3000VS

3000VA - 2250W Line Interactive extended-run tower UPS

More details


€ 1,008.91 VAT incl.
(€ 847.83 + VAT)


tri-0109


Add to my wishlist


OUTPUT
Output Volt Amp Capacity (VA) 3000
Output kVA capacity (kVA) 3
Output Watt Capacity (watts) 2250
Output kW capacity 2.2
Output power factor 0.8
Output Capacity Details Output de-rates to 1600 watts with external battery packs connected
Nominal Output Voltage(s) Supported 230v
Frequency compatibility 50 / 60 Hz
Output voltage regulation (line mode) -19% +8%
Output voltage regulation (Battery mode) +/- 5%
Built-in UPS output receptacles 8 C13 outlet(s); 1 C19 outlet(s)
Included output power cables Includes 3 C13 to C14 output power cables
Built-in controllable switched load banks Three switchable two-outlet C13 load banks
Output circuit breaker 10A (x2) - each breaker protects 4 C13 outlets each, C19 is unbreakered
Basic PDU options PDUNV (1U / 2 C19, 12 C13 outlets)
Metered PDU options PDUMV20HV (0U / 6 C19, 32 C13 outlets)
Switched PDU options PDUMH20HVNET (1U / 8 C13 outlets); PDUMV20HVNET (0U / 4 C19, 24 C13 outlets)
PDU recommendation notes All noted SWITCHED and METERED PDUs require C19 to C20 input cable (P036-006 or similar)
Output AC waveform (AC mode) Sine wave
Output AC waveform (battery mode) PWM sine wave
INPUT
Rated input current (at maximum load) 15.4A
Nominal Input Voltage(s) Supported 230V AC
UPS input connection type C20 inlet
UPS input connection description IEC320-C20 input connection accepts a variety of detachable cordsets to match country or site-specific wall receptacles
BATTERY
Full load runtime (minutes) 4 min. (2250w)
Half load runtime (minutes) 14 min. (1125w)
Expandable battery runtime Extended runtime supported via optional external battery packs
External battery pack compatibility BP48V24-2U (limit 1); BP48V60RT3U (multi-pack compatible)
DC system voltage 48V DC
Battery recharge rate (included batteries) Less than 4 hours from 10% to 90%
Replacement battery cartridge (internal UPS battery replacement) RBC54
Battery Access Battery access door
Battery replacement description Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage regulation description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 151V to 282V
Overvoltage correction Input voltages between 245 and 282 are reduced by 12%
Undervoltage correction Input voltages between 177 and 199 are boosted by 14%
Severe undervoltage correction Input voltages between 151 and 176 are boosted by 30%
LEDS ALARMS & SWITCHES
LED Indicators 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Alarms Audible alarm indicates power-failure, overload and low-battery conditions
Alarm cancel operation Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
Switches 2 Switches control off/on power status and alarm-cancel/self-test operation
SURGE / NOISE SUPPRESSION
UPS AC suppression joule rating 480
UPS AC suppression response time Instantaneous
EMI / RFI AC noise suppression Yes